39
3 INSTALLATION
ELECTRICAL & HYDRAULIC INSTALLATION
The motor control panel contains high
voltage components. Only authorized
service personnel should be allowed
inside. See Lock-Out & Tag-Out in-
structions in the maintenance section.
DANGER
460
VOLTS
A lockable fused disconnect switch (customer furnished) must be installed and be within sight
of the compactor motor control panel location, not to exceed 50'0" from the compactor. This
fused disconnect switch should be sized in accordance with the compactor (see Fuse and
Circuit Breaker Chart).
REMOTE POWER PACK INSTALLATION
1. The remote power pack should be installed and anchored as required by the customer. If
the operator station is mounted in the face of the motor control panel, be certain these
controls are located as to be in a convenient, but not hazardous, location to the customer.
CAUTION: Operator Station must be located so that the Emergency Stop Button is readily
accessible to the operator and within three (3) feet of the charging chamber access door.
If installation requires the operator station to be located in a more remote area, a second
Emergency Stop Button should be added and installed in the manner described above.
2. For a through-the-wall power pack installation, see the diagram THROUGH-THEWALL
POWER UNIT INSTALLATION in this section. Special care should be taken to protect the
hoses from abrasive objects.
3. Connect the hydraulic hoses to the power pack, exercising care to follow the port decals
(A or B) on the packer and the power pack. In the event the decals have been obliterated,
the hose leading from the rear of the cylinder should be installed in the side port of the
block to which solenoid valve is bolted (A Port). The hose leading from rod end of the
cylinder should be connected to the end of the block to which the solenoid valve is bolted
(B Port). Refer to Power Unit diagrams in the Maintenance section of this manual.
DANGER: All equipment must be grounded per National Electric Code.
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded, metal, permanent wiring system; or an
equipment grounding conductor must be run with the circuit conductors and connected to
the equipment grounding terminal or lead on the compactor.
If there is any doubt whether the appliance is properly grounded, a qualified electrician
should be consulted.