6
1 OPERATION
CONTROL PANEL
OPERATOR
STATION
FOR 88SC, 100SC,
250SC, & 250 ULTRA
MANUAL - OFF - AUTOMATIC SWITCH*
KEYED START SWITCH
REVERSE PUSHBUTTON
EMERGENCY STOP PUSHBUTTON
*Optional equipment - not included on standard models
CONTROL DESCRIPTION
1. MANUAL - OFF - AUTOMATIC SWITCH - (
Optional Equipment - not included on
standard models
) This switch controls the compactor operation mode, manual or automatic
(automatic is photocell mode).
2. KEYED START SWITCH - This switch requires a key for operation. Insert the key and
turn clockwise to the START position. Depress and hold the key for one to two seconds
and release. The compactor will cycle the preset number of times determined by the
Multi-Cycle Counter*, then stop. After use, turn the key to the counterclockwise position
and remove the key.
3. EMERGENCY STOP PUSHBUTTON - When depressed, this pushbutton will stop all
powered operation of the compactor.
4. REVERSE PUSHBUTTON - This pushbutton will reverse the compaction ram when
depressed. The motor must be running for the REVERSE button to operate. See the
MANUAL OVERRIDE INSTRUCTIONS on the next page for details of the operation.
*For more information on the Multi-Cycle Counter see page 25.