Rack Monitor 88XX
Document: Installation Manual
Date: January 2024
Version: A.0 subject to change
Page 20 of 30 Installation Manual
Data Communication
The 88XX series rack monitors are equipped with a communication socket designed to support different kind of
protocols due to the versatile world of communications.
Consult OPW for possible communication add-ons.
Finishing Installation
Remove the corrosion protector from the seal and attach it to the door,
Caution: - Make sure, before closing the enclosure that the cables do not get stuck between the
door and the bottom side of the enclosure.
Close the door, make sure to press the hinges completely into the enclosure,
Connect all 12 bolts M8x25,
Warning: Do not leave any bolts out for a safe use.
Tighten the bolts with a minimum of 21 Nm and a maximum torque of 22 Nm (16.2 FtLbs),
Make sure that all earth cables are connected,
Energize the system,
Warning: Do not make modifications to the Rack Monitor 88XX for alternative mounting (with
exception of the mentioned method in Figure 6 and Figure 4) when not making use of the initial
mounting holes in the Rack Monitor 88XX any guarantees will be declined.