Data Communication
The 88XX series rack monitors are equipped with a communication socket designed to support different kind of
protocols due to the versatile world of communications.
Consult OPW for possible communication add-ons.
Finishing Installation
• Remove the corrosion protector from the seal and attach it to the door,
Caution: - Make sure, before closing the enclosure that the cables do not get stuck between the
door and the bottom side of the enclosure.
• Close the door, make sure to press the hinges completely into the enclosure,
• Connect all 12 bolts M8x25,
Warning: Do not leave any bolts out for a safe use.
• Tighten the bolts with a minimum of 21 Nm and a maximum torque of 22 Nm (16.2 FtLbs),
• Make sure that all earth cables are connected,
• Energize the system,
Warning: Do not make modifications to the Rack Monitor 88XX for alternative mounting (with
exception of the mentioned method in Figure 6 and Figure 4) when not making use of the initial
mounting holes in the Rack Monitor 88XX any guarantees will be declined.