3.2 IN GENERAL
Take off the packaging material with care. Take off all the material used for packing and
accessories.
3.3 TO THE ELCTRICIAN
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
Utility connections shall be designed to be disconnected without the use of tools or shall be of
sufficient length to permit the equipment to be moved for cleaning.
WARNING
The electrician must make sure that the supply cable does not come in contact with the oven
top which becomes hot.
3.4 TO THE PLUMBER
This equipment is to be installed to comply with the applicable federal, state or local plumbing
codes.
Utility connections shall be designed to be disconnected without the use of tools or shall be of
sufficient length to permit the equipment to be moved for cleaning.
Connect the steam system (1/2 NPT) to the water distribution network. We highly
recommend a water softener to eliminate scale and minerals in the water. A minimum
water pressure of 60 psi with a hardness reduction filtration system with a minimum flow
rate of 3 gpm is required. We suggest to use CUNO 3M #SF165 or equivalent. Connect the
drain of the oven (1/2 NPT) to the drain system of the building or install a recipient to
retrieve the surplus of hot water from the steam system.