32 Dräger CPS 7900
Technical data
9 Technical data
9.1 General
Sizes in cm:
Sizes in inch:
9.2 Resistance to penetration of infectious
agents
9.3 Resistance of the suit material
Suit
size
Height Chest
measure-
ment
Waist
measure-
ment
For
persons
with
S 150-165 80-118 72-106 <80 kg
M 160-175 80-118 72-106 >80 kg
L 170-185 80-118 72-106 <100 kg
XL 180-200 104-124 95-110 <120 kg
XXL 195-210 104-124 95-110 <140 kg
Suit
size
Height Chest
measure-
ment
Waist
measure-
ment
For
persons
with
S 59-65 31-45 28-41 <175 lb
M 63-69 31-45 28-41 >175 lb
L 67-73 31-45 28-41 <220 lb
XL 71-79 41-48 37-43 <265 lb
XXL 77-83 41-48 37-43 <310 lb
Weight:
without boots approx. 5.1 kg
with boots approx. 6.6 kg
Material:
Suit D-mex
Visor Special polyvinyl chloride
Gloves FKM/butyl or
laminate: HPPE or
K-MEX-Gigant: Para-aramid or
Tricotril: Nitril/para-aramid
Safety boots Nitrile-P
black, FPA-CR safety boots
Socks D-mex
Colours:
Outside/inside blue/grey
orange/grey
olive/grey
beige/grey
Temperatures:
During use -40 °C to +70 °C
1
lower temperatures down to -80 °C are
possible during short-term exposure and
tested for the material D-mex by Dräger,
but not as part of the EU type approval
test.
Observe operating temperatures of the
respiratory protective equipment!
1 tested by Dräger
During storage -30 °C to +60 °C
Test Result Category
1
1 in accordance with EN 14 126:2003+AC:2005
Resistance to contaminated
liquids under hydrostatic
pressure (with the
bacteriophage Phi-X174)
hydrostatic
pressure:
20 kPa
6
Resistance to infectious
agents in the event of
physical contact with
substances containing
contaminated liquids
Breakthrough-
time: >75 min.
6
Resistance to biologically
contaminated dusts
Penetration:
<1 log cfu
3
Resistance to biologically
contaminated aerosols
Penetration:
log r endless
3
Test Result Category
1
1 according to EN 943-1:2015
Abrasion resistance >2000 cycles 6
Flex-cracking resistance >100000 cycles 6
Flex-cracking resistance at
-30 °C
>4000 cycles 6
Tear resistance >40 N 3
Penetration resistance >50 N 3
Resistance to flame
penetration
Self-
extinguishing
3
Seam strength >500 N 6
Tensile strength >1000 N 6