Response Time | < 15 seconds |
---|---|
Display | LCD |
Sensor Type | Catalytic Bead |
Gas Types | Methane, Propane, Hydrogen |
Measuring Range | 0-100% LEL |
Operating Temperature | -40 °C to +65 °C (dependent on sensor) |
Operating Humidity | 0 to 95% RH |
Power Supply | 12-30 VDC |
Battery Life | N/A (Fixed Power Supply) |
Output Signal | 4-20 mA |
Communication | HART |
Ingress Protection | IP66 |
Protection Rating | ATEX, IECEx |
Certifications | ATEX, IECEx |
Target Gas | Combustible gases |
Identifies the specific product series covered by the manual.
Highlights crucial safety instructions to be followed before using the product.
Details technical safety procedures and recommendations for safe device operation.
Outlines the intended applications and necessary conditions for using the device safely.
Instructions for installing the device in Ex d environments without a docking station.
Instructions for installing the device in Ex e environments with a docking station.
Explains how to connect the device with a relay for standalone operation.
Specific instructions for installing an EC sensor onto the Polytron 8100 EC.
General instructions for installing different types of measuring heads.
Important general points to consider before and during the commissioning process.
Describes the layout and function of the device's control panel.
Explains the meaning of the various LEDs and symbols used on the device.
Details the information displayed on the device's screen and their significance.
General information about display indicators applicable to all device models.
Specific symbols relevant to the Polytron 8100 EC model.
Provides an overview of the device's menu structure and options.
Important preliminary information and prerequisites for calibration.
Steps and considerations before performing calibration procedures.
Detailed instructions for performing zero calibration on the device's sensors.
Step-by-step guide for executing the span calibration process.
Key details regarding the automatic calibration feature.
Step-by-step instructions for executing the automatic calibration.
Lists and explains common fault codes and their potential causes.
Explains various warning messages and their corresponding corrective actions.
Instructions for conducting bump tests and verifying response times.
Detailed guide on how to replace the device's sensors.
Specifies the measurement ranges for different gases and sensors.
Information regarding the power supply requirements and relay functionalities.
Details the operating and storage conditions for the device.
Details the ES, BVS 13 ATEX G 001 X test certificate.
Information regarding PFG 14 G 001 X test certificates.
Specifies the certified conditions for using DrägerSensor O2, O2LS, and SensorAlive.
Metrological data and conditions for the DrägerSensor O2 (6809720).