6.6 How to set up LSN50 to work with Single Channel Gateway such as
LG01/LG02?
In this case, users need to set LSN50 to work in ABP mode and transmit in only one
frequency.
Assume we have a LG02 working in the frequency 868400000 now, below is the steps.
Step1: Log in TTN, Create an ABP device in the application and input the network session key
(NETSKEY), app session key (APPSKEY) from the device.
Note: You need to make sure the above three keys match in the device and in TTN. You can
change them either in TTN or in the Device to make them match. In TTN, NETSKEY and
APPSKEY can be configured in the setting page, but the Device Addr is generated by TTN.
You can also change the Device ADDR in TTN by using the The Things Network CLI.