07-01480C 2010-01 6 Dri-Eaz Products, Inc.
TROUBLESHOOTING
FAULT CAUSE SOLUTION
operate
Unit not switched on.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
not start
Unit needs 5 minutes before restart
Overload preventing start up
Switch off unit, wait 5 minutes before starting.Reduce
room temperature to 90°F (32°C) or less.
not turning
Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
but room not dry
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
continuously in
defrost mode
Increase room temperature.
function
little water
Room temperature is too low.
Airflow through unit is restricted
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model Evolution LGR F292-A
Type LGR
Refrigerant R-410A
Use weight 92 lbs. | 42 kg
Power 5 amps, 115 volts
Water removal AHAM
(80°F/60% RH)
70 pts. | 33 liters / day
Max process air 160 CFM | 272 CMH
Operating Range 33–100°F | 1–33°C
Air filter 3M HAF filter (part no. F372)
Power cord
25 ft. | 7.6 m
(H × D × W)
85 × 52.5 × 52.5 cm
Construction Rotomolded polyethylene housing
Safety
ETL certified to UL 474 and CSA
22.2 no. 92
Specifications are subject to change without notice. Some
values may be approximate.
Warranty information is available at www.dri-eaz.com.