3.4 Hydraulic Hoses
Always make sure that any Hydraulic Hoses tted into the Oil Cooler system
are of the correct length to suit the positioning of the equipment being
installed.
Allow for the movement of the PTO/Gearbox in relation to the Hydrapak
when tting the hydraulic hoses. See Fig 4, a and b.
Installation
DO NOT Install hydraulic
hoses that are too long and
may kink’ when tted.
CAUTION
Install the Hydrapak a safe
distance away from the
vehicle exhaust or other heat
producing equipment. See Fig
5.
NOTE
Fig. 4a. Hose Lengths too short 4b. Too long.
Fig. 5 Vehicle exhaust / heat producing equipment
a
b
DO NOT Install hoses that are
too short and will be stretched
when tted.
CAUTION
The Hydrapak body must
not be distorted or heavily
stressed when mounting.