EasyManua.ls Logo

DSC maxsys PC4020KT - PC4020 CONTROL PANEL WIRING DIAGRAMS; PC4020 CONTROL PANEL WIRING DIAGRAM

DSC maxsys PC4020KT
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
PC4020 CONTROL PANEL
WIRING DIAGRAMS
R-1
T- 1
RNG
TIP
BATTERY
12 VDC
MINIMUM
4Ah
+RED
-
BLK
COMBUS TO
ALL MODULES
BELL LOOP
700 mA MAX
BE SURE TO OBSERVE
POLARITY WHEN
CONECTING POLARIZED
SIRENS OR BELLS
NORMALLY CLOSED
CONTACT;
NO END OF LINE
RESISTOR
ANY Z
TERMINAL
ANY COM
TERMINAL
2 NORMALLY OPEN
CONTACTS WITH
5600 END OF LINE
RESISTOR
ANY Z
TERMINAL
ANY COM
TERMINAL
2 NORMALLY CLOSED
CONTACTS WITH
END OF LINE
RESISTOR
ANY Z
TERMINAL
ANY COM
TERMINAL
1 NORMALLY OPEN
CONTACT AND
1 NORMALLY CLOSED
CONTACT WITH
END OF LINE
RESISTOR
ANY Z
TERMINAL
ANY COM
TERMINAL
TYPICAL ZONE CIRCUITS
TELEPHONE CONNECTION
GROUND CONNECTION
120 V
40 VA
TRANSFORMER
16-18 V @ 40 VA
DO NOT CONNECT TO
RECEPTACLE
Nut
Washer
Cabinet
Bolt
Ground
Rod
TO GROUND
CONNECTION
INCOMING LINE
FROM TELEPHONE
COMPANY
OUT TO TELEPHONE
EQUIPMENT ON
PREMISES
GRY
BRN
RED
GRN
*
Recommended use with Double EOL Resistors.
5600 End Of Line resistor colour bands: Green/Blue/Red/Gold
ALARM
CONTACT
DOUBLE EOL CIRCUIT
1 NORMALLY CLOSED
CONTACT WITH
5600 END OF LINE
RESISTORS
ANY Z
TERMINAL
ANY COM
TERMINAL
*
DOUBLE EOL CIRCUIT
2 NORMALLY CLOSED
CONTACTS WITH
5600 END OF LINE
RESISTORS
ANY Z
TERMINAL
ANY COM
TERMINAL
*
ALARM
CONTACT
TAMPER
CONTACT
AUX
1 AM
P
BELL
5 AM
P
BATT
5 AM
P

Table of Contents

Related product manuals