EasyManua.ls Logo

DSC maxsys PC4020KT - SYSTEM OVERVIEW; Maximum System Capabilities; Voice Prompting Module (VPM); LCD Keypads (LCD4500)

DSC maxsys PC4020KT
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Maximum System Capabilities
Control Units - 1 PC4020 Main Board
128 Zones
PC4020 Main Board: 16 zones
PC4108 Expansion Module: 8 zones
PC4116 Expansion Module: 16 zones
PC4164 Expension Module: 64 wireless zones
64 High Current Outputs - Up to 16 PC4204 Modules
144 Low Current Outputs
- 9 PC4216 16 Output Modules
1 RS-232 Interface - PC4400
PC4700 Fire Module Support
16 Remote LCD Keypads - LCD4500
Escprt 4580 Voice Prompting Module
1 Main Board Fully Programmable Output
1 12 VDC Switched Fully Programmable Auxiliary Power
Supply (Main Board)
1 Supervised Fully Programmable Bell/Siren Output
(Main Board)
1 Telephone Interface (Main Board)
2 Telephone Interface (PC4700)
128 Programmable Zones
16 zones on main board expandable by using 8 and 16
zone modules
18 zone types including: instant, 2 types of interior, 3
delay, 3 fire, 4-24 hour, forced answer, momentary,
maintained arming, Links supervisory and Links answer.
Zone expansion is done by enrolling a zone expansion
module
Zones can be assigned independently to any partition(s)
Programmable for NC loops, EOL resistor or Double EOL
resistors
Voice Prompting Module (VPM)
All main user function accessible through the VPM
Local and remote access abilities
241 word library for zone, access code and partition labelling
LCD Keypads (LCD4500)
Total of 16 on the system
Can be assigned to any partition
Single keypad system control
211 Outputs
1 main board transistor switch to ground with 3A
capabilities (programmable for 1 of 28 options)
64 relay outputs programmable for 1 of 28 options each
(16-4204 modules with 4 outputs each)
144 switched transistor outputs programmable for 1 of
28 options each (9-4216 modules with 16 outputs)
1 switched Aux output
1 PGM switched to ground
Switched Auxiliary Output
Programmable for 1 of 28 options
5 Enclosures
PC4001C - PC4020 plus 2 modules
PC4002C - 3 modules
PC4003C - 1 module
PC4004C - Attack resistant for PC4020 plus 2
modules
PC3000 - PC4820
Supervised Alarm Output
Bell Output, 700 mA fused at 5 Amps,
12 V
DC - commercial and 11.6 - 12.6 VDC - residential
Steady or Pulsed Output
Programmable for 1 of 28 options
Event Buffer
3000 events
Date and time stamp
Event Buffer Viewing - any System Master is able to view 2500
events through the keypad including date and time stamp
Event Buffer Printing - the entire event buffer (3000 events)
can be printed at once through the Installer’s mode
8 True Partitions
Separate or shared zones from other partitions
Individual keypads per partition
Individual access codes for each partition
Individual keypad zones (Fire, Auxiliary, Panic)
Individual outputs programmable per partition
RS-232 Interface Module (PC4400)
Used to output data to a local printer
PC4820 Access Control Module
Total of 16 on the system
Two access card readers
Is used to control access to secure areas of the system
Can control two doors that may be assigned to any partition
on the system
Can be used to arm/disarm partitions on the system
Internal Memory
Retains programmed data even when both AC and Battery
have been removed.
The clock will have to be reset after a power down
condition which will be indicated by an audible trouble
beep and the keypad trouble LED is on.
Keypad User Options
They are all menu driven, including:
Programming of several types of 4 or 6 digit access codes,
128 in total
Bypassing from the keypad by authorized personnel
Utility functions such as remote control of lights, door
strikes, etc.
Communicator
Communicates in all 10 and 20 BPS single line and
extended formats
Radionics Rounds and Radionics Parity
Sescoa Superfast format
Ademco Contact ID format
SIA 1986 format
Sur-gard 4/3 DTMF format
3/1 and 4/2 formats
Hexadecimal numbers
DTMF and Pulse dialing
DPDT line seizure
True dial tone detect
Anti-jam feature
Three telephone numbers and nine account codes
LINKS Support
3 telephone numbers for LINKS
Auto programming for LINKS zones
SYSTEM OVERVIEW

Table of Contents