42
[702] Second International Options Code
Default Option ON Off Section Page #
OFF I_______I 1 Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60 5.5 17
ON I_______I 2 Force Dialing enabled Force Dialing disabled 5.5 17
OFF
I_______I 3 Land line Test Transmission in minutes Land line Test Transmission in days 5.14 23
OFF I_______I 4 1600 Hz Handshake Standard Handshake 5.9 19
OFF I_______I 5 ID Tone enabled ID Tone disabled 5.5 17
OFF
I_______I 6 2100 HZ ID Tone 1300 Hz ID Tone 5.5 17
OFF I_______I 7 One Time 1-Hr User enabled DLS Window Full 6-Hr User enabled DLS Window 5.10 20
OFF I_______I 8 Bell on FTC when armed FTC Trouble only when armed 5.5 17
[703] Delay Between Dialing Attempts
(Section 5.5 “Communicator – Dialing” on page 17)
Default: 001 I_________I________I________I (Valid entries are 000-255 Seconds)
Module Programming
[801] PC5400 Printer Module Programming
Please refer to your PC5400 Installation Manual for installation and programming instructions.
[803] Alternative Communicator Programming
Please refer to your LINKS2X50 Installation Manual for installation and programming instructions.
[804] PC5132 Wireless Expansion Programming
Please refer to your PC5132 Installation Manual for programming locations and instructions.
Special Installer Functions
[901] Installer Walk Test Mode Enable / Disable (Section 5.32 “Walk Test (Installer)” on page 27)
[902] Module Supervision Reset (Section 2.7 “Removing Modules” on page 5)
[903] Module Supervision Field (Section 2.6 “Supervision” on page 5)
[904] Wireless Module Placement Test
For more information, please refer to your PC5132 Installation Manual
• Select the module / transmitter (Zones 01-32).
• Press [#] to Cancel.
Placement Led Keypad LCD Keypad Bell / Buzzer
Good Light 1 ON Steady “GOOD” 1 Beep / Squawk
Fair Light 2 ON Steady “FAIR” 2 Beeps / Squawks
Bad Light 3 ON Steady “BAD” 3 Beeps / Squawks
[990] Installer Lockout Enable
(Section 5.31 “Installer’s Lockout” on page 27)
[991] Installer Lockout Disable (Section 5.31 “Installer’s Lockout” on page 27)
[993] Restore Alternative Communicator to Factory Default Programming
(Section 5.30 “Resetting Factory Defaults” on page 27)
[996] Restore PC5132 to Factory Default Programming (Section 5.30 “Resetting Factory Defaults” on page 27)
[997] Restore PC5400 to Factory Default Programming (Section 5.30 “Resetting Factory Defaults” on page 27)
[999] Restore PC1565 to Factory Default Programming (Section 5.30 “Resetting Factory Defaults” on page 27)