SPECIAL FUNCTION COMMAND
The PC2000 can be programmed at the time the system is installed to operate
other devices such as electric door strikes, door openers, electric lights,
cameras, etc. by a command from the keypad. This special function is activated
by pressing
[s]
then
[7].
PROGRAMMING OTHER SYSTEM FEATURES
Before any of the following functions can be programmed, enter
[*I,
[8]
and
[master code]. The ‘PROGRAM’ light will be flashing.
Press
[l]
then enter any [two digits] (from 01 to 99) to set the “ENTRY TIME” in
seconds. The “ENTRY TIME” is the time allowed between opening the
exit-entry door and entering the security code to disarm the
PC2000.
Press
[2]
then enter any [two digits] (from 01 to 99) to set the “EXIT TIME” in
seconds. The “EXIT TIME” is the time allowed between arming the PC2000 and
exiting the exit-entry door.
Press
[3]
then enter any [two digits] (from 01 to 99) to set the “ALARM
CUT-OFF TIME” in minutes. The “ALARM CUT-OFF TIME” is the length of
time the siren or bells will ring before shutting off.
Press
[4]
to turn on the “QUICK-ARM” feature. The keypad sounder will beep
quickly 3 times. The “QUICK-ARM” feature allows entering
[*I
then
[O]
to arm
the PC2000 in place of a
[4
digit code]. [x] [0] will not disarm the
PC2000.
Pressing
[4]
again will turn
off
“QUICK-ARM”. The sounder will give one long
beep.
Press
[5]
to turn on the “AUTO-ARM” feature. The sounder will beep 3 times.
The “AUTO-ARM” leature arms the PC2000 at the same time each day. The
keypad sounder starts one minute before the programmed arming time (see
[
*]
[6]
command for programming “AUTO-ARM” time). The arming sequence may
be stopped by pressing any key. At the end of one minute the PC2000 will be
armed. Pressing
[5]
again will turn off “AUTO-ARM”. The sounder will give one
long beep.
Press
[S]
to turn on the “ALERT” feature. The sounder will beep 3 times. The
“ALERT” feature is used, while the panel is disarmed, to provide a tone from the
keypad each time a door or window is opened or closed. The specific doors and
windows which provide indication are determined at the time of installation.
Pressing
[S]
again will turn off the “ALERT”. The sounder will give one long
beep.