DSC Power Series PC1616 PC1832 PC1864 System Manual
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]
Bypassing Zones with a PK5500/LCD5500 Keypad
Start with disarming the system.
1. Press [*] to enter the function menu. The keypad will display “Press [*] for < > Zone Bypass”.
2. Press [1] or [*] or , then your [access code] (if required). The keypad will display “Zone Search < >
Zone Name”.
3. Enter the two-digit number of the zone(s) to be bypassed (01-64). You can also use the [< >] keys to
find the zone to be bypassed, and then press [*] to select the zone.
The keypad will display “Zone Search < > “Zone Name?”. “B” will appear on the display to show that
the zone is bypassed. If a zone is open (e.g., door with door contact is open), the keypad will display
“Zone Search < > “Zone Name” O”. If you bypass the open zone, a “B” will replace the “O”.
4. To unbypass a zone, enter the two-digit number of the zone(s) to be bypassed (01-64). You can also
use the [< >] keys to find the zone, and then press [*] to select the zone. The “B” will disappear from
the display to show that the zone is no longer bypassed.
5. To exit bypassing mode and return to the Ready state, press [#].
Bypassing Zones with a PK5500/LCD5500 Keypad
Start with disarming the system.
1. Press [*][1], then your [access code] (if required).
2. Enter the two-digit number of the zone(s) to be bypassed (01-64). On PK5508/PK5516/PC55XXZ
keypads, the zone light will turn on to indicate that the zone is bypassed.
3. To unbypass a zone, enter the two-digit number of the zone (01-64). On PK5508/PK5516/PC55XXZ
keypads, the zone light will turn off to indicate that the zone is not bypassed.
4. To exit bypassing mode and return to the Ready state, press [#].
Activating All Bypassed Zones
To activate all bypassed zones:
1. Press [*][1], then your [access code] (if necessary).
2. Press [0][0].
3. To exit bypassing mode and return to the Ready state, press [#].
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press [*][1], then your [access code] (if necessary).
2. Press [9][9].
3. To exit bypassing mode and return to the Ready state, press [#].

Other manuals for DSC Power Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Power Series and is the answer not in the manual?

DSC Power Series Specifications

General IconGeneral
BrandDSC
ModelPower Series
CategorySecurity System
LanguageEnglish

Related product manuals