DSC Power Series PC1616 PC1832 PC1864 System Manual
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]
The system can generate two different alarm sounds:
Continuous Siren = Intrusion (Burglary Alarm)
Temporal/Pulsed Siren = Fire Alarm
Intrusion (Burglar) Alarm Continuous Siren
If you are unsure of the source of the alarm approach with caution! If the alarm was accidental, enter
your Access Code to silence the alarm. Call your central station to avoid a dispatch.
Fire Alarm Pulsed Siren
Follow your emergency evacuation plan immediately! If the fire alarm was accidental (i.e. burned toast,
bathroom steam, etc.), enter your Access Code to silence the alarm. Call your central station to avoid a
dispatch. Ask your alarm company if your system has been equipped with fire detection. To reset the
detectors, see the Sensor Reset section.
Trouble Conditions
When a trouble condition is detected, the Trouble or System indicator will turn on, and the keypad will
beep every 10 seconds. Press the [#] key to silence the beeps. Press [*][2] to view the trouble condition.
The Trouble or System indicator will flash. The corresponding trouble will be represented by numbers 1-
8.
LED/Digit Trouble Condition Comments
1
Service Required
(Press [1] for more
information)
(1) Low Batt (2) Bell Circuit (3) System Trouble (4) System Tamper (5)
Modulate Supervision (6) RF Jam Detected (7) PC5204 Low Batt (8)
PC5204 AC Failure
2 Loss of AC Power
If the building and/or neighborhood has lost electrical power, the
system will continue to operate on backup for several hours.
3 Telephone Line Fault The system has detected that the telephone line is cut.
4
Failure to
Communicate
The system attempted to communicate with the monitoring station, but
failed. This may be due to Trouble 3.
5 Sensor (or Zone) Fault The system is experiencing difficulties with one or more sensors.
6
Sensor (or Zone)
Tamper
The system has detected a tamper condition with one or more sensors
on the system.
7
Sensor (or Zone) Low
Batt
If the system has been equipped with wireless sensors, one or more
has reported a low battery condition.
8 Loss of Time & Date
If complete power was lost, the time and date will need to be re-
programmed.
Trouble Menu Acknowledgement

Other manuals for DSC Power Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Power Series and is the answer not in the manual?

DSC Power Series Specifications

General IconGeneral
BrandDSC
ModelPower Series
CategorySecurity System
LanguageEnglish

Related product manuals