EN50131-1 Installation Requirements
For EN50131-1 compliant installations,the following programming options shall be set as described.
Supervision Heartbeat (required for ATS4 and ATS5):
l
[851][004] set to 0087h (135s heartbeat).
NOTE: The compatible receiver at ARC location shall have supervision window programmed for 1800s (ATS4) or 180s (ATS
5).
l
[851][005] options 1 and 3 shall be enabled
Testtransmission (required for ATS3):
l
[851] System test options [026] and [027] shall be enabled (FF) for the communication paths available.
l
[851][124] and [125] shall be programmed with time of day for test transmission and 1440 minutes (24h) for test trans-
mission cycle
Configuration of communication paths (all ATS classes)
l
[300][001] selectoption 02 for auto routing (this will allow transmission of the events over all available communication
paths in the system)
l
[380] enable option 5 (YES) for parallel transmission over all available communication paths (if redundant configuration is
desired)
l
[382] enable option 5 (YES) this will enable Alternate communicator
l
[384] enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3 back-up for receiver 1).
Technical Specifications, Ratings and Compatibility
Table 1: Communicator Ratings
Model TL280(R)
Power Supply Ratings
Input Voltage
10.8-12.5 VDC. Power is supplied from the panel’s PC-Link header or a
PCL-422 module in remote cabinet installations. In remote cabinet
installations, the PCL-422 module located with the communicator is
powered by either an HSM2204 or an HSM2300. Refer to the PCL-422
installation instructions for details.
Current Consumption
Current 100mA @ 13.66V
Environmental Specifications
Operating Temperature -10°C to 55°C
Humidity 5% ~ 93% relative humidity, non-condensing
Mechanical Specifications
Board Dimensions (mm) 100 × 150 × 15
Weight (grams) with bracket 290
Table 2: Compatible Receivers and Panels
Communicator Receiver/Panel Description
3G2080(R) Receiver
l Sur-Gard System I-IP Receiver, version 1.13+
l Sur-Gard System II Receiver, version 2.10+
l Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
TL2803G(R) Panel
l HS2016
l HS2032
l HS2064
l HS2128
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Communicator Installation Configuration
This Ethernet communicator shall be installed by service persons only (service person is defined as a person having the appro-
priate technical training and experience necessary to be aware of hazards to which that person may be exposed to in