EasyManua.ls Logo

DSC TL280 - Communicator Wiring and Connection; Electrical Connections and Diagram; Wiring Warnings

DSC TL280
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 2: HS2016/2032/2064/2128 Control Panel
PC-Link cable connector
screw
GSM Radio
RJ-45
UA601
HS2016/2032/2064/2128
WARNING! - Modules are power limited. Do not route any wiring over the circuit board. Maintain at least 1in. (25.4mm)
separation between circuit board and wiring. A minimum of ¼ in. (7mm) separation must be maintained at all points
between non-power limited wiring and power limited wiring.
3.
To electrically connect the communicator to the panel, perform the following steps (See Figure 3).
a. Disconnectboth AC power and battery connections from the panel, and disconnecttelephone line.
Figure 3: Communicator Wiring Diagram
AUDIO/DEFAULT
DSC
UA601
PC-LINK
COM
TL280(R)
AC
AC
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
AUX+
BELL +
PGM1 PGM3
RING
T-1
HS2016/2032/2064/2128
UA621
Input Ratings:
+10.8V ~ +12.5 VDC
100mA
DSC Panel min. power requirements:
- 16.5 VAC 40 VA transformer;
- 12 VDC 7Ah battery
Jumper pins 4 and 5
to reset.
1
From NID
Use only CAT5
Supervised
RJ-45
GRN
YEL
TIP
R-1
BLK
RED
AUX -
BELL -
EGND
TX+
GND
TX-
RX+
RX-
SHLD
Network Link
YELLOW
PGM2 PGM4
Maximum cable length
100 m (328 ft)
PCLINK_2
Red
Red
RS-232
To 3rd party device
4. Install the RS-323 connections (R models only). If using the communicator with a third party device, wire the connections
as per the table below.Maximum cable length for RS-232 cable is 8 ft. (2.4 m).
NOTE: Please refer to the installation manual for the third party device for wiring instructions.