Section 4: Programming Options
Device Label
This section is used to program a custom label for the
device.
Default: Zone ZZZ
Valid range: 32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See on page 43 for attribute definitions.
Door Chime Enabled
Alarm Report Enabled
Burglary Verified Enabled
Transmission Delay Enabled
Bell Audible Enabled (read-only)
Bell Steady Enabled (read-only)
Bypass Enable Enabled (read-only)
Force Arm Disabled (read-only)
Swinger Shutdown Enabled (read-only)
Two Way Audio Enabled (read-only)
Talk Listen Enabled (read-only)
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default: Enabled
Valid range: Enabled/Disabled
4.6.7 Wireless Temperature Con-
figuration Options
The following sections are used for programming wireless
temperature sensors.
Note: Wireless temperature feature was not evaluated by
UL/ULC.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default: Enabled
Valid range: Enabled/Disabled
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default: Enabled
Valid range: 1
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default: Disabled
Valid range: Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default: 24-hour Temperature
Valid range: 24-hour Temperature
Device Label
This option is used to program a custom label for the wire-
less device.
Default: Zone ZZZ
Valid range: 32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See on page 43 for attribute definitions.
Door Chime Disabled
Alarm Report Enabled
Burglary Verified Disabled
Transmission Delay Enabled
Bell Audible Enabled (read-only)
Bell Steady Enabled (read-only)
Bypass Enable Enabled (read-only)
Force Arm Disabled (read-only)
Swinger Shutdown Disabled (read-only)
Two Way Audio Disabled (read-only)
Talk Listen Disabled (read-only)
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
- 35 -