Section 4: Programming Options
Default: Enabled
Valid range: Enabled/Disabled
Temperature Format
This section is used to select the scale temperature is dis-
played in.
Default: F
Valid range: F (Fahrenheit), C (Celsius)
High Temperature Warning
This option is used to set the temperature threshold for activ-
ating the High Temperature warning indicator. A high tem-
perature warning sounds an audible alert but does not
send a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default: 999
Valid range: -999 to 999
High Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the High Temperature alarm.
This option is disabled by entering -999 or 999.
Default: 999
Valid range: -999 to 999
Low Temperature Warning
This option is used to set the temperature threshold for activ-
ating the Low Temperature warning indicator. A low tem-
perature warning sounds an audible alert but does not send
a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default: 999
Valid range: -999 to 999
Low Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the Low Temperature alarm.
This option is disabled by entering -999 or 999.
Default: 999
Valid range: -999 to 999
4.6.8 Wireless Flood Configurations
The following sections are used for programming wireless
flood sensors.
Note: Wireless Flood feature was not evaluated by UL/ULC.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default: Enabled
Valid range: Enabled/Disabled
Device Partition Assignment
This option is used to assign the wireless device to an avail-
able partition.
Default: 1
Valid range: 1
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default: Disabled
Valid range: Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This programming section is used to program a zone type
for the device.
Default: Interior Follower
Valid
range:
Instant, Interior Follower, Interior Stay/Away, Delay
Stay/Away, 24 Hour Supervisory Buzzer, 24 Hour Non
Alarm
Device Label
This section is used to program a custom label for the
device.
Default: Zone ZZZ
Valid range: 32 character ASCII
Zone Attribute
This option is used to customize zone operation. The fol-
lowing attributes are available for the temperature sensor:
Door Chime Disabled
Alarm Report Enabled
Burglary Verified Disabled
Transmission Delay Enabled
Bell Audible Enabled (read-only)
Bell Steady Disabled (read-only)
Bypass Enable Disabled (read-only)