Appendix 2: Reporting Codes
Section # Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
Siren 12 tamper/restore alarm T/R E (3)83-812 / R (3)83-812 TA-0812 / TR-0812
Siren 13 tamper/restore alarm T/R E(3)83-813 / R (3)83-813 TA-0813 / TR-0813
Siren 14 tamper/restore alarm T/R E (3)83-814 / R (3)83-814 TA-0814 / TR-0814
Siren 15 tamper/restore alarm T/R E(3)83-815 / R (3)83-815 TA-0815 / TR-0815
Siren 16 tamper/restore alarm T/R E (3)83-816 / R (3)83-816 TA-0816 / TR-0816
Repeater 1 tamper/restore alarm T/R E(3)83-901 / R (3)83-901 TA-0901 / TR-0901
Repeater 2 tamper/restore alarm T/R E(3)83-902 / R (3)83-902 TA-0902 / TR-0902
Repeater 3 tamper/restore alarm T/R E(3)83-903 / R (3)83-903 TA-0903 / TR-0903
Repeater 4 tamper/restore alarm T/R E(3)83-904 / R (3)83-904 TA-0904 / TR-0904
Repeater 5 tamper/restore alarm T/R E(3)83-905 / R (3)83-905 TA-0905 / TR-0905
Repeater 6 tamper/restore alarm T/R E(3)83-906 / R (3)83-906 TA-0906 / TR-0906
Repeater 7 tamper/restore alarm T/R E(3)83-907 / R (3)83-907 TA-0907 / TR-0907
Repeater 8 tamper/restore alarm T/R E(3)83-908 / R (3)83-908 TA-0908 / TR-0908
Keypad Lockout - Incorrect access code entry T/R E(4)61-000 / R(4)61-000 JA-0000
Opening Events
User Openings - Disarmed by user O/C E(4)A1-UUU OP-UUUU
Automatic Arming Canceled O/C E(4)64-UUU CI-0000
Special Opening - System disarmed using: keyswitch, main-
tenance code, DLS software, wireless key
O/C E(4)AA-000 OP-0000
Closing Events
User Closings - System armed by user, wireless key O/C R(4)A1-UUU CL-UUUU
Partial Closing - 1 or more zones bypassed when armed O/C E(4)56-000 CG-0000
Special Closing - System armed via: quick arm, keyswitch,
function key, maintenance code, DLS software
O/C R(4)AA-000 CL-0000
Exit Fault O/C E(3)74-ZZZ EA-ZZZZ
Automatic (Schedule) Closing O/C R (4)A3-000 CA-0000
System Trouble Events
General system tamper/restore (while armed) MA/R E(1)37-000/ R(1)37-000 ES-0000/EJ-0000
General system tamper/restore (while disarmed) MA/R E(1)37-000/ R(1)37-000 ES-0000/EJ-0000
Battery trouble/restore - Main panel MA/R E(3)A2-000 / R(3)A2-000 YT-0000 / YR-0000
Battery absent trouble/restore - Main panel MA/R E(3)11-000 / R(3)11-000 YM-0000 / YR-0000
Battery charging trouble/restore MA/R E(3)14-000/ R(3)14-000 YP-0000/ YQ-0000
Panel AC trouble/restore - Main panel MA/R E(3)A1-000 / R(3)A1-000 AT-0000 / AR-0000
Battery over voltage charge/restore MA/R E(3)14-000/ R(3)14-000 YP-000/YQ-000
Alternate Communicator
Alternate Communicator radio/SIM trouble/restore MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
Alternate CommunicatorGSM Network trouble/restore MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
- 52 -