10- MAINS CONNECTION
EVO with electronic ballast operates at 90-260Vac 50-60 Hz.
Prior to connecting the unit to your mains supply, ensure that the model in your
possession correctly matches the mains supply available.
For connection purposes, ensure that your plug is capable of supporting 3,5 amps
at 230Vac, or 7,5 amps at 90Vac each unit connected.
Strict adherence to regulatory norms is strongly recommended.
MAINS OUTPUT 90-260Vac 50-60 Hz (16A Max)
Max 4 EVO Units @ 230Vac
Max 2 EVO Units @ 120Vac
MAINS INPUT 90-260Vac 50-60 Hz
FUSE
8AT
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each EVO.
A good earth connection is essential for the correct operation of the projector.