9
Owner's Manual for Duke Flexbake 5
TM
Proof and Bake Oven
INSTALLATION
UNPACKING UNIT
Inspect the shipping carton and/or container,
carefully noting any exterior damage on
the delivery receipt; also note any damage
not evident on the outside of the shipping
container (concealed damage). Contact the
carrier immediately and le a damage claim
with them. Save all packing materials when
ling a claim. Freight damage claims are the
responsibility of the purchaser and are not
covered by the warranty.
• Follow the instructions on the Carton Box
for unpacking the unit.
• Inspect unit for damage such as, broken
glass, etc.
• Report any dents or breakage to source of
purchase immediately.
• Do not attempt to use unit if damaged.
• Remove all materials from unit interior.
• If unit has been stored in extremely cold
area, wait a few hours before connecting
power.
UNIT PLACEMENT
• Do not install unit next to source of heat,
such as deep fryer, etc.
• Install unit on level surface oor.
• Minimum Clearance of 6" (152mm) must
be maintained between the unit and any
combustible substance.
• Either side of the unit must remain open
for proper airow for electrical component
cooling. One side may be installed without
clearance. Maintain a minimum clearance
of 2 inches on the rear of the unit for
proper operation and cooling.
WARNING
ELECTRICAL SHOCK HAZARD UNIT
MUST BE SAFETY GROUNDED,
EARTHED.
DO NOT MODIFY, DEFEAT
ELECTRICAL CONNECTIONS OR
ALTER PLUG.
ELECTRICAL CONNECTIONS
BEFORE CONNECTING
THE UNIT TO THE POWER
SOURCE, VERIFY THAT THE
VOLTAGE AND PHASE OF THE
POWER SOURCE ARE IDENTICAL
TO THE VOLTAGE AND PHASE
INFORMATION ON THE DATA
LABEL.
ELECTRICAL AND
GROUNDING CONNECTIONS MUST
COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL
ELECTRICAL CODE AND/OR OTHER
LOCAL ELECTRICAL CODES.
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
THE MAIN SWITCH
ON THE APPLIANCE IS FOR
STANDBY POWER ONLY. FOR ALL-
POLE DISCONNECT REMOVE PLUG
FROM WALL OUTLET.