➊Installation Requirement
a. Long arm forklift or crane at less 1 tons
b. It requires a proper area for placing the cutter, about 79CM*230CM, the floor
should be as flat as possible.
c. It requires a clean room without EMI or static interference and operates under
circumstance with humidity of 50-80%Rh and 20-25℃.
d. Compressed air supply: 4-8kg/cm^2, no less than 1.5HP.
➋Placement
a. Extend feet of the cutter (to the height that higher than the wheels) with
adjustable wrench after place the cutter in position
b. Level the system is very important
c.
Stacking Tray Install and adjust proper size for paper