Operating and Maintenance Instructions
EN
LC.2 – LC.4 – LB.5 – LB.6 – LB.8 – LC.12 – LC.20
8
8702036 – 12/04/2016 – R.7 www.dvp.it
3.3.3 Model: LB.6 – LB.8
A
B
A
Intake
3
Oil drain plug
7
Motor rating plate
B
Air outlet
4
Oil sight glass
8
Terminal board
1
Motor fun guard
5
Oil filler plug
Only present on special versions
2
Attachment point
6
Information plate
TECHNICAL SPECIFICATIONS
LB.6 LB.8
50 Hz 60 Hz 50 Hz 60 Hz
Inlet capacity m³/h
6 7 8 9
Final pressure (Abs.) mbar - hPa
2
Max inlet pressure for water vapour mbar - hPa
- - - -
Max water vapour pumping rate kg/h
- - - -
Motor power
kW (1~ / 3~)
0,25 / 0,25 0,30 / 0,30 0,25 / 0,25 0,30 / 0,30
Nominal r.p.m. n/min
2800 3300 2800 3300
Noise level (UNI EN ISO 2151) (K 3dB) dB(A)
58 60 58 60
Weight
kg (1~ / 3~)
10,0 / 9,0
Type of oil cod. DVP
BV32 (SW40)
Oil quantity d
0,20
Pump Intake / Outlet “G
3/8
Continuous-duty working renge (Abs.) mbar - hPa
- - - -
Operating temperature (room temp. 20°C) °C
65 ÷ 70 70 ÷ 75 70 ÷ 75 75 ÷ 80
Required room temp. for place of installation °C
12 ÷ 40
Ambient temperature for storage/transport °C
-20 ÷ 50
MAX humidity / altitude
80% / 1000m a.s.l. *
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.