TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The burner will not
light with a match
1. Match not reaching burners
(when holding match with hand).
2. Gas supply shut off.
3. Poor connection between gas
hose plug tting and sleeve
coupling.
4. Burner inlet blocked.
1. Use match holder found in
cabinet door.
2. Check that the natural gas supply
shut-off valve is open.
3. Turn off the grill knobs, close the
gas supply shut-off valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi) and
burner as described by the Care
and Maintenance section in the
manual.
No gas ow or an
obstructed gas ow
1. Gas supply shut off.
2. Poor connection between gas
hose plug tting and sleeve
coupling.
3. Burner inlet blocked.
1. Check that the natural gas supply
shut-off valve is open.
2. Turn off the grill knobs, close the
gas supply shut-off valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
3. Clean the burner inlet (venturi) and
burner as described by the Care
and Maintenance section in the
manual.