grntfiF
DY 4000
Manual
&
Automatic
Glose Timers
Note: lf value is
set to
zero,
the timer is deactivated and the activations
put
on
terminal number 2 is now in manual operation.
4.2
Setting AC/LOOP Timer
1. Press
and
release
AC/LOOP timer button on the Dynalogix ll controller.
The display will change to: AG Delay_Timer=##.
See figure 4.2-1.
AC/LOOP
Timer
Figure
4.2-1: AC/LOOP Timer
2.
Use the Up and Down arrow buttons to change the countdown time to the
desired duration. The Dynalogix llwill
automatically save any changes that
are made. See Figure
4.2-2.
lncrease
Setting
Decrease
Setting
Figure 4.2-2: Raise/Lower AC/LOOP
Timer
Note: AC/LOOP timer is also used when the reversing
edge
is
triggered
Note: lf value is
set to
zero
door
will
come down after it reaches the open limit.