W
gltrltftO
4.0
DY
4000
Manual
&
Automatic
Close Timers
Setting the
Manual
&
Automatic
Glose Timers
The Dynalogix ll has
two automatic close timers. The first timer, MG/PB
timer,
will count down
after a activation
is
installed on terminal number 2
(most
commonly
used for
pull
cords or
pushbuttons).
MC/PB
timer also can be
turned on or off, making it manual
operation or automatic operation simply by
assigning a
countdown
value
to the timer. The second timer, AC/Loop timer,
will
count down after
a
activation is installed
on terminal 4
(most
commonly
used are motion sensors and loops). lf this
timer
is
set to
zero,
the door will
come down after door reaches
upper
limit.
4.1
Setting
MC/PB Timer
'1.
Press
and
release MC/PB Timer
button on the Dynalogix ll controller.
The
display
will
change to: MC Delay_Time=##.
See
figure 4.1-1.
MC/PB
Timer
Figure
4.1-1: MC/PB Timer
2.
Use the Up and Down arrow buttons to
change the countdown time to the
desired duration. The Dynalogix llwill automatically
save any changes that
are made. See fioure 4.1-2.
lncrease
Setting
Decrease
Setting
Figure 4.1-2:
Raise/Lower Manual Timers
-ffif
ih?i:
-Wil
@
V
M!NU-
'"rr*
|
8
DYNACO
USA, INC,
7/e.4a&n
caDaaz
Sd/4rq
ADear:fn