16-044 www.powercommander.com 2009-2013 Honda Goldwing/FB6 - PCV - 7
23 Route the main wiring harness of the SFM to the connector bundle shown in
Figure O.
FIG.N
19 Use 2 of the supplied Velcro strips to secure the Secondary Fuel Module to
the top of the right air scoop at the location shown in Figure N.
Clean the surface with the supplied alcohol swab prior to applying the Velcro.
20 Plug the supplied CAN Termination Plug into one of the expansion ports at the
top of the SFM module.
This is a hard plastic CAN port plug supplied in the kit. This is a crucial step
that is often overlooked.
21 Plug the supplied CAN link cable into the other expansion port on the SFM
module and route the CAN link cable to the primary PCV module on the
opposite (left) air scoop.
Route the cable beneath the ECM and reverse gear servo.
22 Plug the other end of the CAN link cable into the PCV module.
FIG.O
24 Locate and unplug the pair of stock BLACK 4-pin connectors in this bundle
(Fig. P).
There are 2 pairs of BLACK 4-pin connectors in this bundle. Unplug the pair
that has RED, PINK, and BROWN colored wires.
FIG.P
Unplug