EasyManua.ls Logo

E-stim 2B - Throb Mode; Thrust Mode; Random Mode; Step Mode

E-stim 2B
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Throb Mode
T
h
r
o
b
6
6
A
:
1
0
0
%
L
B
:
1
0
0
%
A continuous mode with the pulse feel cycling between 10 and the adjustment value.
Nice and relaxing. Adjustments values are between 10 and 100.
Thrust Mode
T
h
r
u
s
T
6
6
A
:
7
8
%
L
B
:
1
0
%
Similar to Throb, Thrust is a continuous mode. with the pulse feel cycling between 10
and the adjustment value and then back to 0. Adjustments values are between 10 and
100.
Random Mode
R
a
n
d
o
m
7
8
:
5
0
A
:
6
7
%
L
B
:
M
A
X
The random mode is designed to produce a random pulse output The adjustment
control allows the user to adjust the ‘randomness’ of the pulse range, from 2 to 100.
Lower numbers give a much faster random pulse stream. The second value, is the pulse
feel, that allows you to adjust the sensation of each individual pulse, from soft to spiky.
Step Mode
S
t
e
p
3
4
:
5
0
A
:
1
0
%
L
B
:
7
9
%
Step mode is designed to step the output up in individual steps, allowing the subject to
get used to the current level, before the output is stepped up to the next level.
The output steps between 0 and the current Channel level with a delay between step
controlled by the Adjust Control, from 2 to 100. The second value, is the pulse feel, that
allows you to adjust the sensation of the pulse stream, from soft to spiky. Each step is set
to 1%.
Lower values, give a faster step.
Because of the delay of the programmed step, any changes in output level, will only
occur at the next step change.
18