- 28 -
4.2 Weight Scale - Error Codes
Error
Code
Possible Cause Solution
uuuuuu
Overloaded condition.
Wrong connection at load cell.
Load cell has quality problem.
Reduce the weight.
Check load cell connection.
Inspect load cell for damage.
Check the input and output.
nnnnnn
Overloaded condition.
Bad connections.
Load cell has quality problem.
Check scale is resisted or not, foot is kept level
or not.
Check load cell connection.
Check input and output resistance of load cell.
ERR1
Overweight calibration error.
Incorrect weight input or incorrect
weight on weighing platform.
Input weight correctly during calibration.
Place correct weight on weighing platform.
ERR2
Underweight calibration error.
Incorrect weight input or incorrect
weight on weighing platform.
The calibration weights Minimum is 10% of
Max. cap. Recommend 60%-80% of Max.
Capacity.
ERR3
During calibration, the input signal is
negative.
Check all connections. Check load cell. If
connections and load cell are okay, PCB needs
replacing.
ERR4
During calibration, the signal is
unstable.
After the platform is stable, start calibration.
ERR5
Circuitry error Replace the PCB.
ERR6
System error Call for Tech Support