18
SPECIFICATIONS cont.
AC Voltage Models (5770X-41X)
Range: 199.9 mVAC, 1.999 VAC, 19.99 VAC, 199.9 VAC, DIP Switch
Selectable, all ranges true RMS
Frequency: 40 to 1000 Hz
Impedance: 1 M W (capacity coupled)
Overrange: 750 VDC/530 VAC except 220 VDC/AC on 199.9 mV range
Accuracy: +/- 0.5% of reading, +/- 0.13% FS, +/- 0.5 digit, +/- 180 PPM/°C
for crest factor = 1 plus +/- 0.7% for crest factor = 1 to 3
and +/- 2.5% for crest factor = 5
DC Current Models (5770X-42X)
Range: +/- 199.9 mADC, +/- 1.999 mADC, +/- 19.99 mADC, +/- 199.9
mADC, DIP Switch Selectable
Impedance: 199.9 mV/selected range
Overrange: 30 mA (199.9mA range), 100 mA (1.999 mA range), 300 mA (19.99
mA range), 1A (199.9 mA range)
Accuracy: +/- 0.1% of reading, +/- 0.03% FS, +/- 0.5 digit, and +/- 120 PPM/°C
AC Current Models (5770X-43X)
Range: 199.9 mAAC, 1.999 mAAC, 19.99 mAAC, 199.9 mAAC, DIP Switch
Selectable, all ranges true RMS
Frequency: 40 to 1000 Hz
Impedance: 199.9 mV/selected range (shunt output capacitively coupled)
Overrange: 30 mA (199.9mA range), 100 mA (1.999 mA range), 300 mA
(19.99 mA range), 1A (199.9 mA range)
Accuracy: +/- 0.5% of reading, +/- 0.13% FS, +/- 0.5 digit, and +/- 200
PPM/°C for crest factor = 1 plus +/- 0.7% for crest factor = 1 to 3
and +/- 2.5% for crest factor = 5
5A AC Models (5770X-44X)
Range: 5A AC, true RMS
Frequency: 40 to 1000 Hz
Impedance: 0.02 ohms (shunt output capacitively coupled)
Overrange: 10A Maximum
Accuracy: +/- 0.4% of reading, +/- 0.13% FS, +/- 0.5 digit, and +/- 200 PPM/°C
for crest factor = 1 plus +/- 0.7% for crest factor = 1 to 3
and +/- 2.5% for crest factor = 5
Process Models (5770X-45X)
Range: 4-20 mADC, 0-10 VDC, 1-5 VDC; separate input terminals for
voltage and current signals
Impedance: 100 W (current input) and 1.27 M W (voltage input)
Overrange: 50 mA maximum (current input) and 100 V maximum
(voltage input)
Power Output: 24 VDC +10%/-12%, 90 mA max, short circuit protected
Accuracy: +/- 0.1% of reading, +/- 0.03% FS, +/- 0.5 digit, and +/- 80 PPM/°C

Other manuals for Eaton Durant Eclipse Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Durant Eclipse Series and is the answer not in the manual?

Eaton Durant Eclipse Series Specifications

General IconGeneral
BrandEaton
ModelDurant Eclipse Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals