MAU-00046AD - Page 4
Nova AVR 625/1250
1
3
8
4
7
5
7
8
6
4
3
2
1. Power on/off switch 4. AC output 7. USB port for USB models (B type)
2. Indicator 5. Fuse 8. Telephone line / modem protection
3. AC input 6. Circuit breaker
4. LED and Audible Alarm operation Table
Nova AVR 500
LED Status Audible Alarm UPS Status
Green ON
(On/Off switch)
None UPS on normal operation
Green ON
(On/Off switch)
1 beep every 10 seconds UPS on battery power
Green ON
(On/Off switch)
1 beep every 2 seconds
UPS on battery power
Low battery level
Green ON Continuous beep Internal failure/load short
Green Blinking Continuous beep Overload, reduce load
Nova AVR 625/1250
LED Status Audible Alarm UPS Status
Green ON
(On/Off switch)
None UPS on normal operation
Green ON
(On/Off switch)
1 beep every 10 seconds UPS on battery power
Green ON
(On/Off switch)
1 beep every 1 second
UPS on battery power
Low battery level
!
Red ON Continuous beep Internal failure
!
Red Blinking 1 beep every 0.5 second Overload, reduce load
Red ON None Battery fault