Eaton Sefelec DXS506 User Manual

Eaton Sefelec DXS506
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SEFELEC REFERENCE PENT0438
Operating manual XS SERIES - English

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Eaton Sefelec DXS506 and is the answer not in the manual?

Eaton Sefelec DXS506 Specifications

General IconGeneral
BrandEaton
ModelSefelec DXS506
CategoryTest Equipment
LanguageEnglish

Summary

Specifications

Power supply

Details about mains voltage, frequency, and fuses for the XS series units.

1 DIELECTRIC STRENGTH TEST 50VA (hipot 50VA test)

Maximum current limit : IMAX

Permanent current measurement

DIELECTRIC STRENGTH TEST 500VA (hipot 500VA test)

2 DIELECTRIC STRENGTH TEST 10VA

Output voltage

Output voltage specifications for 10VA Hipot tests.

Breakdown detection

Breakdown detection modes for 10VA Hipot tests.

3 Megohmmeter function (insulation resistance measurement)

500V megohmmeter function

Details on the 500V megohmmeter function.

1000V megohmmeter function (option XS26 or MXS1000)

1500V megohmmeter function (SXS16)

Measurement voltage

Adjustable voltage for 1500V megohmmeter.

Measurement threshold

Setting thresholds for 1500V megohmmeter.

4 Ground continuity function

Measurement current

Current settings for ground continuity function.

Measurement thresholds

Timer

Front panel description

Liquid Crystal Display (LCD) description

Rear panel description

Installation

Power ON

Operator safety advices

Crucial safety warnings for operating the unit.

Connection to a specimen

Connection for the ground continuity measurement

How to connect specimens for ground continuity tests.

6 Unit configuration

Access control to the parameters

Interface selection

Sequence selection (Option 04)

7 Insulation resistance measurement

Parameter setting

Accessing and modifying insulation resistance test parameters.

Measurement voltage selection

Setting the test voltage for insulation resistance.

Measurement threshold selection

Defining PASS/FAIL thresholds for insulation resistance.

Timer operation

8 Dielectric strength test (hipot test)

To set the RISE and FALL times

Breakdown detection mode selection

IMIN and IMAX threshold adjustment

Delta I level adjustment

Parameter memorization

9Ground continuity resistance measurement

Setting

Setting parameters for ground continuity measurement.

Measurement current selection

Selecting the test current for ground continuity.

Resistance threshold selection

Ground continuity resistance measurement

10 Sequence mode operation (SXS)

How to run a simple sequence

Multiple ground continuity

Multiple ground continuity operation

Multiple ground continuity followed by a dielectric strength test ( automatic sequence)

12 Input output Interfaces

Input-Output for Programmable Logic Controller Interface (PLC)

Using the PLC interface for unit control and data acquisition.

Connections

Description of the input output signals

Insulation resistance measurement

Precautions to be observed

Measurement voltage selection

Dielectric strength tests

Dielectric strength tests with a dc voltage

Ground continuity measurement

Current selection

Selecting the appropriate current for ground continuity tests.

14 Safety interlock connector (C5)

15 Measurement I/O on the rear panel

16 Maintenance and calibration

CALIBRATION

Operation of the XS 4-wire option in XS hipot function

Related product manuals