EasyManua.ls Logo

Eaton Sefelec RXS56 User Manual

Eaton Sefelec RXS56
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SEFELEC REFERENCE PENT0438
Operating manual XS SERIES - English

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Eaton Sefelec RXS56 and is the answer not in the manual?

Eaton Sefelec RXS56 Specifications

General IconGeneral
BrandEaton
ModelSefelec RXS56
CategoryTest Equipment
LanguageEnglish

Summary

Specifications

Power Supply Specifications

Details mains voltage, frequency, and fuse ratings for the XS series.

Dielectric Strength Test 50VA (Hipot 50VA Test)

Dielectric Strength Test 500VA (Hipot 500VA Test)

Output Voltage Specifications

Details the voltage range, stability, and accuracy of the output voltage.

Breakdown Detection Methods

Explains detection modes like Delta I, IMAX, and FIMAX for identifying breakdowns.

Dielectric Strength Test 10VA

Breakdown Detection Methods

Explains the Delta I mode for detecting breakdowns in the 10VA test.

Megohmmeter Function

500V Megohmmeter Function

Details measurement voltage, range, and accuracy for the 500V model.

1000V Megohmmeter Function

Details measurement voltage, range, and accuracy for 1000V models.

1500V Megohmmeter Function

Details measurement voltage, range, and accuracy for the 1500V model.

Ground Continuity Function

Measurement Current and Voltage

Specifies the test current range and open circuit voltage for continuity tests.

Introduction and Operating Instructions

Front Panel Description

Details the layout and function of the instrument's front panel controls.

Rear Panel Description

Describes the connectors and controls located on the rear panel.

Unit Configuration

Insulation Resistance Measurement

Parameter Setting

Details how to access and modify measurement parameters like voltage and thresholds.

Measurement Voltage and Threshold Selection

Explains how to set test voltage and define HI/LO limits for PASS/FAIL criteria.

Timer Operation

Describes setting measurement duration and rise/fall times for resistance tests.

Dielectric Strength Test (Hipot Test)

Setting Test Parameters

Covers setting voltage, hold time, rise/fall times, and breakdown detection modes.

Test Voltage Selection

Details how to select appropriate AC or DC test voltages based on standards.

Breakdown Detection Modes

Explains various modes like IMAX, FIMAX, and Delta I for fault detection.

Timer Operation Modes

Describes AUTO, DEFAULT, and MANUAL timer modes for the test.

Sequence Mode Operation

Input Output Interfaces

Safety Interlock Connector (C5)

Maintenance and Calibration

Related product manuals