SEFELEC REFERENCE PENT0438
Operating manual XS SERIES - English

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Eaton Sefelec DXS56 and is the answer not in the manual?

Eaton Sefelec DXS56 Specifications

General IconGeneral
BrandEaton
ModelSefelec DXS56
CategoryTest Equipment
LanguageEnglish

Summary

Dielectric Strength Test 50VA (Hipot 50VA)

XS50 / XS56 Model Details (5kVAC / 6kVDC)

Specific parameters for XS50/XS56 models during dielectric testing.

Voltage and Current Parameters

Details on output voltage, reading, accuracy, and short circuit current.

Current Limit Settings and Modes

1 µA Current Resolution Option

Threshold Setup

Configuration of ΔI, IMAX, IMIN, FIMAX thresholds.

Current Measurement Accuracy

Accuracy specifications for AC and DC current measurements.

Dielectric Strength Test 500VA (Hipot 500VA)

XS500 / XS506 Model Details (5kVAC / 6kVDC)

Specific parameters for XS500/XS506 models during dielectric testing.

Output Voltage and Current Parameters

Details on output voltage, reading, accuracy, and short circuit current.

Breakdown Detection and Delta I Mode

Explains breakdown detection methods including the ΔI mode.

Current Limit Settings and Modes (500VA)

Dielectric Strength Test 10VA (XS16 Model)

XS16 Model Details (10kVDC)

Specific parameters for XS16 model during dielectric strength testing.

Breakdown Detection Overview

Explains the general methods for detecting breakdowns.

Current Limit Settings and Modes (10VA)

Maximum Current Limit (IMAX)

Setting the maximum current limit for tests.

Fast Maximum Current Limit (F(ast)IMAX)

Faster detection of maximum current limit.

FIMAX + ΔI Mode

Combines FIMAX and Delta I modes.

IMAX + ΔI Mode

Combines IMAX and Delta I modes.

Measurement Procedures and Controls (10VA)

Permanent Current Measurement and Fault Indication

Direct current measurement and methods for indicating faults.

Timer Operation Modes

Controls test timing with MANUAL, DEFAULT, and AUTO modes.

Detection of Capacitive Samples

3 Megohmmeter Function (Insulation Resistance Measurement)

500V Megohmmeter Function Details

Details for 500V megohmmeter functionality, including voltage and range.

Measurement Thresholds and Timer

1000V Megohmmeter Function (Option XS26 or MXS1000)

1500V Megohmmeter Function (SXS16)

Measurement Threshold Settings

Setting high and low limits for PASS/FAIL results.

4 Ground Continuity Function

Ground Continuity Settings and Controls

Measurement Thresholds

Setting high and low thresholds for good/bad continuity.

5 Introduction and Operating Instructions

General Safety Warning

Warning about qualified personnel and essential safety precautions.

Installation Procedures

Power ON and Safety

Power ON Procedure

Steps to power on the unit.

Operator Safety Advice

Critical safety precautions for operating the unit.

Specimen Connection

6 Unit Configuration

Sequence Selection (Option 04)

7 Insulation Resistance Measurement

Measurement Threshold Selection

Setting high and low limits for PASS/FAIL results.

Insulation Resistance Measurement Execution

Error Messages for Insulation Resistance

Lists common error messages like SAFETY LOOP, OVER-RANGE, etc.

8 Dielectric Strength Test (Hipot Test)

Breakdown Detection Mode Selection

Selecting breakdown detection modes (ΔI, IMAX, FIMAX, OFF).

Current Limit Settings (IMAX, FIMAX, IMIN)

Setting maximum (IMAX, FIMAX) and minimum (IMIN) current limits.

Combined Current Variation Modes

Using FIMAX+ΔI and IMAX+ΔI modes for advanced detection.

IMIN and IMAX Threshold Adjustment

Delta I Level Adjustment

Capacitive Sample Detection and Parameter Memorization

Activation of Capacitive Sample Detection

Enabling capacitive sample detection before tests (SXS16 only).

Expert Mode and Ramp Settings

Breakdown Detection Mode Selection During Ramps

Selecting breakdown detection modes specifically for voltage ramps.

IMAX and Delta I Thresholds Adjustment During Ramps

Adjusting IMAX and Delta I thresholds for voltage ramps.

Configuration of Minimum Capacity Value to Detect

Dielectric Strength Test (Hipot Test) Execution

Dielectric Strength Tests with DC Voltage

Breakdown Detection Mode Selection (DC)

Selecting breakdown detection modes for DC tests, including IMAX, ΔI, and OFF.

Ground Continuity Measurement

14 Safety Interlock Connector (C5)

16 Maintenance and Calibration

Calibration Recommendations

Information on annual calibration and available kits.

Operation of the XS 4-Wire Option in Hipot Function