Operating manual XS SERIES - English

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Eaton Sefelec MXS1000 and is the answer not in the manual?

Eaton Sefelec MXS1000 Specifications

General IconGeneral
BrandEaton
ModelSefelec MXS1000
CategoryTest Equipment
LanguageEnglish

Summary

WARRANTY

1 DIELECTRIC STRENGTH TEST 50VA (hipot 50VA test)

2 DIELECTRIC STRENGTH TEST 10VA

Breakdown detection

Configuration of breakdown detection modes and current limits for 10VA tests.

Timer

Configuration of test timing modes for 10VA Dielectric Strength tests.

3 Megohmmeter function (insulation resistance measurement)

500V megohmmeter function

Details the 500V function for insulation resistance measurements.

4 Ground continuity function

Measurement thresholds

Sets HI and L LIMIT thresholds for Ground Continuity PASS/FAIL.

6 Unit configuration

Filtering configuration for capacitive specimen

Configures filter modes (NORMAL, CAPACITOR, R.H.TIME) for capacitive samples.

Access control to the parameters

Sets password protection levels (UNLOCKED, READ ONLY, LOCKED) for parameters.

Password programming

Procedure for setting or modifying the unit's access password.

Remote trigger mode

Enables triggering measurements using external accessories or contacts.

Interface selection

Allows selection of communication interfaces like RS232, IEEE488, ETHERNET.

Sequence selection (Option 04)

Enables automatic cycling of insulation, Hipot, and continuity tests.

EXPERT mode Activation

Activates expert mode for advanced control over test parameters.

7 Insulation resistance measurement

Parameter setting

Screen for adjusting parameters like voltage, limits, and hold time.

Measurement voltage selection

Allows selection of the DC test voltage for insulation resistance.

Measurement threshold selection

Sets HI-LIMIT and LO-LIMIT for PASS/FAIL determination.

8 Dielectric strength test (hipot test)

Setting

Screen for adjusting Hipot test parameters: voltage, hold, rise, fall times.

Test voltage selection

Allows selection of AC or DC test voltages for Hipot tests.

IMAX and delta I thresholds adjustment during the ramps

Adjusts IMAX and delta I thresholds during voltage ramps.

Configuration of the minimum capacity value to detect

Sets minimum capacity threshold for capacitive sample detection.

9 Ground continuity measurement

Resistance threshold selection

Sets HI and L LIMIT thresholds for Ground Continuity PASS/FAIL.

Timer operation

Configures timer modes (AUTO, DEFAULT, MANUAL) for Ground Continuity.

Power ON

Operator safety advices

Essential safety precautions to prevent electrical shock and damage.

Connection to a specimen

Connection for the ground continuity measurement

Details how to connect specimens for Ground Continuity measurement.

10 Sequence mode operation (SXS)

Sequence setting

Sets up automatic or manual sequences of tests.

How to run a simple sequence

Step-by-step guide to execute a basic test sequence.

Sequence with manual control

Enables manual control over sequence execution flow.

Multiple ground continuity

Configures testing multiple ground continuity points on a specimen.

Multiple ground continuity operation

Details the operation of multiple ground continuity tests.

Multiple ground continuity followed by a dielectric strength test ( automatic sequence)

Describes sequences combining ground continuity and dielectric strength tests.

11 Accessories with remote control feature

Operation

Explains how to use remote control accessories for test start/stop.

Specific case for the sequence (SXS50 & 500)

Addresses special considerations for using remote controls with SXS sequences.

12 Input output Interfaces

Input-Output for Programmable Logic Controller Interface (PLC)

Details PLC interface for automated control and data acquisition.

Electrical specifications

Provides electrical specifications for PLC interface inputs and outputs.

Dielectric strength tests

Breakdown detection mode selection

Explains leakage current control modes (IMAX, ΔI) for breakdown detection.

Ground continuity measurement

14 Safety interlock connector (C5)

16 Maintenance and calibration

4 wires option for XS series and hipot function XS108-109

Operation of the XS 4-wire option in XS hipot function