Eaton Tripp Lite Series Cloud Connected UPS Systems User Guide 934859—Rev B 63
Table 9. Protection Characteristics
BC350RNC(AG-075F) BC600RNC(AG-0760) BC850RNC(AG-0761)
UPS AC suppression joule
rating
190 (AC)
UPS AC suppression
response time
Instantaneous
Overload protection
Line Mode: 110% - Enter fault after five minutes; 120% - enter fault immediately.
Battery Mode: 110% shutdown in five seconds; 120% shutdown immediately
Table 10. Battery Characteristics
BC350RNC(AG-075F) BC600RNC(AG-0760) BC850RNC(AG-0761)
Battery type
Sealed, maintenance-free, lead acid batteries.
Battery voltage / AH Qty (1) 12V / 2.8AH Qty (1) 12V / 3.6AH Qty (1) 12V / 6AH
Battery charge current
.5A
Battery float voltage
13.7 VDC
Recharge time
8 hours
Backup time
2 min / full load
7 min / half load
1.2 min / full load
5 min / half load
1.7 min / full load
8 min / half load
Low voltage shutdown
voltage
9.8V all load levels
Min voltage for cold start
11V
Hot-swappable battery
No
Table 11. Environment
BC350RNC(AG-075F) BC600RNC(AG-0760) BC850RNC(AG-0761)
Humidity 0-95% RH @ 0-40 C (non-condensing)
Audible noise
<40 dBA (1 m from the front side)
Storage temperature
-15 to +50 ℃
Operating temperature
0 to +50 ℃
Operating elevation
0-2000 meters
Table 12. Weights and Dimensions
BC350RNC(AG-075F) BC600RNC(AG-0760) BC850RNC(AG-0761)
Net Weight, lb. (kg) 4.6 lbs (2.1 kg) 4.8 lbs (2.2 kg) 7 lbs (3.2 kg)
H x W x D, in. (cm)
2.2 x 10.0 x 7.0 (5.8 x 25.5 x 18.0)
3.1 × 11.0 × 7.0 (8.0 ×28.0
×18.0)
Product Specifications