5 What to do if …?
5.1 Describe possible errors and faults, causes and
remedies
Display Remedy / Customer
The button flashes. Wait for automatic detection.
The unit combination is not permitted. Check the wiring and correct any errors.
Short-circuit in the button of the EasyStart Web. Check the wiring and remove the button if necessary. If the error
is still queued, replace Easy Start Web, otherwise replace defective
button.
Short circuit in the temperature sensor. Check the wiring and remove the sensor if necessary. If the error
is still queued, replace Easy Start Web, otherwise replace defective
sensor.
No connection between EasyStart Web and the server.
Ensure GSM network supply.
Check the fuse and correct error if necessary.
The heater does not exist. Check the wiring and fuse of the heater and correct error if
necessary.
The heater settings stored on the web server do not match the
EasyStart Web setting.
Perform automatic detection again by removing the fuse.
The measured value of the temperature sensor is invalid.
Check the wiring and correct any errors.
Replace the temperature sensor.
The optional control unit is not responding. Check the wiring and correct any errors.
Undervoltage detected by EasyStart Web. Charge the battery.
Check the heater's power supply.
No communication possible between EasyStart Web and the heater. Check the wiring and fuse of the heater and correct error if
necessary.
The heater is not responding. Check the wiring and fuse of the heater and correct any errors.
The heater has a hardware fault. Perform the diagnosis at the heater.
You do not have access to this EasyStart Web. Ask the customer for the approval code.
EasyStart Web is not ready for use. Ensure GSM network supply.
Check the fuse and correct error if necessary.
Unable to find EasyStart Web with the access code. Contact the support service.
Use of the service is not enabled for this EasyStart Web. Renew service.
The heater cannot be switched on using the button. Check the heater's fuse.
Contact the support service.
Check whether the heater has been installed correctly.
Check whether EasyStart Web has been configured suitable for the
heater.
A programmed timer is not executed. Delete timer and reprogram.
12 22.1000.34.5106.0D EN | 06.2019
Operating instructions | EasyStart Web

Other manuals for Eberspächer EasyStart Web

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eberspächer EasyStart Web and is the answer not in the manual?

Eberspächer EasyStart Web Specifications

General IconGeneral
BrandEberspächer
ModelEasyStart Web
CategoryControl Unit
LanguageEnglish

Related product manuals