EasyManua.ls Logo

ebm-papst S4D350-AN08-50 - User Manual

ebm-papst S4D350-AN08-50
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating instructions
S4D350-AN08-50
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
11. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1.1 Hazard levels for warnings
11.1 Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualifications
11.2 Staff qualifications
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
authorized technical staff.
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
1.4 Voltage
11.4 Voltage
; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
When working on an electrically charged device, stand on a
rubber mat.
21.5 Safety and protective features
21.6 Electromagnetic radiation
21.7 Mechanical movement
21.8 Emissions
21.9 Hot surface
21.10 Transport
21.11 Storage
32. INTENDED USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Data according to Commission Regulation (EU) 327/2011
53.4 Technical description
63.5 Mounting data
63.6 Transport and storage conditions
64. CONNECTION AND STARTUP
64.1 Mechanical connection
64.2 Electrical connection
74.3 Connection in terminal box
94.4 Connection diagram
104.5 Opening additional cable glands
104.6 Checking connections
104.7 Switching on the device
104.8 Switching off the device
105. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
115.1 Cleaning
115.2 Safety inspection
115.3 Disposal
Item no. 11661-5-9970 · ENU · Change 206588 · Approved 2019-11-18 · Page 1 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Question and Answer IconNeed help?

Do you have a question about the ebm-papst S4D350-AN08-50 and is the answer not in the manual?

Overview

This document describes the S4D350-AN08-50 device, an ebm-papst Mulfingen GmbH & Co. KG product, intended for conveying air as a built-in component. It is designed for use in power systems with grounded neutral (TN/TT power systems) and operates within an ambient air pressure range of 800 mbar to 1050 mbar. The device is suitable for operation within specified ambient temperature ranges, which are detailed in the technical specifications. Proper use requires adherence to all protective devices and the operating instructions.

Function Description

The S4D350-AN08-50 is a three-phase external rotor motor fan, primarily designed for air conveying applications. Its core function involves moving air efficiently, making it suitable for integration into various customer equipment and systems. The fan operates with an impeller and rotor system, which, when powered, creates an airflow in the direction indicated as "V" on the product drawing. The direction of rotation is counterclockwise when viewed toward the rotor. The device is a built-in component, meaning it is integrated into a larger system, and the responsibility for adequate safeguarding lies with the owner of the system.

Important Technical Specifications

  • Motor Type: M4D074-DF
  • Weight: 4.9 kg
  • Size: 350 mm
  • Motor Size: 74
  • Number of Blades: 5
  • Airflow Direction: V
  • Direction of Rotation: Counterclockwise, viewed toward rotor
  • Degree of Protection: IP44 (installation- and position-dependent as per EN 60034-5)
  • Insulation Class: "F"
  • Moisture (F) / Environmental (H) Protection Class: H1
  • Installation Position: Shaft horizontal or rotor on bottom; rotor on top on request
  • Condensation Drainage Holes: On rotor side
  • Mode: S1
  • Motor Bearing: Ball bearing
  • Touch Current (according to IEC 60990, measuring circuit Fig. 4, TN system): < 0.75 mA
  • Electrical Hookup: Terminal box, variable
  • Protection Class: I (with customer connection of protective earth)
  • Conformity with Standards: EN 60335-1, motor does not have factory-installed overheating protection; CE, EAC, CCC
  • Rotor Surface: Painted black
  • Blade Material: ABS plastic
  • Guard Grille Material: Steel, coated with black plastic (RAL 9005)
  • Nominal Voltage / VAC: 230V (Delta connection) or 400V (Star connection)
  • Frequency / Hz: 50 Hz or 60 Hz
  • Speed (rpm) / min-1: 1370 (50 Hz) or 1520 (60 Hz)
  • Power Consumption / W: 170 (50 Hz) or 230 (60 Hz)
  • Current Draw / A: 0.64 (230V, 50Hz) to 0.70 (230V, 60Hz) or 0.37 (400V, 50Hz) to 0.40 (400V, 60Hz)
  • Max. Back Pressure / Pa: 90
  • Min. Ambient Temperature / °C: -25
  • Max. Ambient Temperature / °C: 65 (50 Hz) or 55 (60 Hz)
  • Starting Current / A: 1.9 (230V) or 1.1 (400V)
  • Overall Efficiency nes / % (Actual): 29.6
  • Efficiency Category: A (Static)
  • Efficiency Grade N: 41.1
  • Power Consumption Pe / kW: 0.15
  • Air Flow qv / m³/h: 2095
  • Pressure Increase Total psf / Pa: 83
  • Specific Ratio: 1.00

Usage Features

  • Installation: The device is designed for mechanical connection by securing it with screws of strength class 8.8. It is crucial to ensure stress-free attachment to the substructure and secure positioning until all fastening screws are tightened. The fan must not be strained on fastening.
  • Electrical Connection: Connection to a power supply requires careful attention to safety. A protective earth connection must be established first. Only cables meeting specified installation regulations for voltage, current, insulation material, and capacity should be used. Cables should be routed to prevent contact with rotating parts. The device is a built-in component and lacks a disconnecting switch, so it must be connected to circuits that can be switched off with an all-pole disconnection switch.
  • Terminal Box: Wires are connected within a terminal box. The cable gland must be sealed, and connections must be strain-free. Cable routing should ideally form a U-shaped loop to prevent water ingress, especially for fans installed lying flat. For upright installations, cable glands should be at the bottom, and cables routed downward.
  • Motor Protection: The device is supplied without automatic overheating protection. For versions without a thermal overload protector, a suitable motor protection switch must be installed externally to prevent overheating and potential fire hazards.
  • Voltage Control: If speed control is implemented via transformers or electronic voltage regulators (e.g., phase control), current overshoots, noise, and vibration may occur. The heating-up of the motor under voltage control must be checked by the customer after installation.
  • Variable Frequency Drive: For operation with variable frequency drives, sinusoidal filters (working on all poles) must be installed between the drive and the motor. These filters protect against high-voltage transients and harmful bearing currents. The motor's heating-up must be checked by the customer.
  • Intended Use Limitations: The device is not intended for operation in an unbalanced state, with severe vibration, in medical life-sustaining equipment, for conveying solids or abrasive/corrosive particles (unless specifically designed), with high dust content, near flammable materials, in explosive atmospheres, or as a safety component. Any modifications or operation with disassembled protective devices are prohibited.

Maintenance Features

  • Cleaning: Regular cleaning is essential for proper operation and to prevent soiling, which can cause overheating and vibration, shortening the fan's service life. Cleaning should only be performed when the fan is not in motion, with the power supply interrupted and secured against renewed switch-on. Dry cleaning, such as with compressed air, is the preferred method. Aggressive cleaning agents, water jets, high-pressure cleaners, acids, alkalis, solvents, or sharp-edged objects must not be used. All cleaning agents must be completely removed.
  • Safety Inspection: Regular safety inspections are recommended every 6 months. This includes:
    • Contact protection cover: Visual inspection for intactness or damage.
    • Device for damage to blades and housing: Visual inspection.
    • Fastening the cables and protective earth terminal: Visual inspection to ensure they are fastened.
    • Insulation of cables: Visual inspection for damage.
    • Tightness of cable gland: Visual inspection.
    • Condensation drainage holes: Visual inspection for clogging.
    • Welds: Visual inspection for crack formation.
    • Abnormal bearing noise: Acoustic check.
    • Loose connections and defective cables should be replaced immediately.
  • Bearing Lifetime: The fan is equipped with maintenance-free ball bearings designed for a service life of 40,000 hours. If bearing replacement becomes necessary after this period, ebm-papst should be contacted.
  • Vibration Management: Low-vibration operation must be ensured across the entire speed control range. Severe vibration can indicate inexpert handling, transport damage, imbalance, or structural resonance. Speed ranges with excessively high vibration levels should be identified during commissioning and either avoided or remedied.
  • Storage: If the device is out of use for some time, it is recommended to switch it on for at least two hours to evaporate any condensation and move the bearings.
  • Disposal: The product components are mostly steel, copper, aluminum, and plastic, which are generally recyclable. Components should be separated into categories (steel and iron, aluminum, non-ferrous metal, plastics, insulating materials, cables and wires, electronic scrap) for proper disposal. Ferrite magnets can be disposed of like normal iron and steel. Country-specific legal regulations for disposal must always be observed. Disassembly should be performed or supervised by qualified personnel.

ebm-papst S4D350-AN08-50 Specifications

General IconGeneral
Brandebm-papst
ModelS4D350-AN08-50
CategoryFan
LanguageEnglish