6. PARTITION HANDLING
6.1. ARMING / DISARMING WITH SELECTING PARTITIONS
1. Enter the number of the function and confirm using . Then enter
the user code and press . 3-tone beep will confirm the correct code
input.
2. LEDs 1 and 2 will display the current partition state. LED on – partition armed,
LED off - partition disarmed. Only LEDs indicating the partitions the user has
access to will be on.
3. To change the partition state press buttons with partition numbers (LEDs with
relevant partition number will go on/off). Press to arm selected
partitions in the away mode. Pressing and holding the will arm the
selected partitions in the stay mode. 3 beeps will confirm the change. To
cancel the entered changes, press .
4. If partition arming in the away/auto mode was selected, the keypad will
indicate counting the time for leaving the facility. Leave the facility before the
time for leaving expires. After it is armed the ARMED LED will be constantly
on.
5. If the partition arming in the stay mode was selected, system will arm
immidiately. ARMED LED will turn on.
6. If partition disarming is selected, the relevant partition will be immediately
disarmed.
6.2. QUICK ARMING / DISARMING PARTITIONS
1. Enter the number of the function ( for partition one or
for partition two) and confirm using . Then enter the user code and press
to arm in the away/auto mode. To arm in the stay mode, press and hold
the button. 3-tone beep will confirm the correct code input.