CPX200NB ALARM CONTROL UNIT USER MANUAL 17 / 30
EN
7 Other damages
To display more detailed information about other damages, press
button.
1 Clock fault
2 Fault of central unit settings
3
Keypads tamper
To display more detailed information about keypads tamper, press
button.
1 Keypad tamper 1
2 Keypad tamper 2
3 Keypad tamper 3
To return to the
Other damages
, press
button.
To return to the main fault menu, press .
7.3. ZONE BLOCKING
The zone blocking function allows de-activating stand-by mode of any zones or
bypassing any damaged lines. Also, zones which are not in stand-by mode and which
the user has access to can be blocked. Zones remain blocked until de-arming.
System informs the user about that fact with quickly flashing LED marked with the
number of the blocked zone.
Zone blocking:
1. Enter the number of the function and confirm with . Enter the
user code and press . 3-tone beep will confirm the correct code input.
Note: If incorrect code is entered the keyboard will emit long
constant sound. Enter the correct code once again.
2. Use buttons numbered 1 to 7 to select zones you want to block.
3. Change the zones blocking status by pressing numbered buttons (LEDs with
relevant zone number will go on/off). Press to confirm blocking of
selected zones. 3 beeps will confirm the change. To cancel the entered
changes, press .
7.4. ADDING A NEW USER
You can add a new user code here. New codes can be added by the administrator
only. 3 beeps will confirm the successfully entered function. Default admin code:
1111.
Note: Individual code cannot be the same; if any code is the
same as another one, it will not be recorded.