EasyManua.ls Logo

Ebyte E108-GN Series - Return Message Interval; Set NMEA Output Frequency; Query NMEA Output Frequency; Return the NMEA Output Frequency

Ebyte E108-GN Series
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co.,Ltd. E108-GN User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
2
23
Example:
$PGKC201*2C<CR><LF>
7.2.15 Return message interval
Command:202
Interval for returning NMEA messages (response to 201 command)
Arguments:None
Example:
$PGKC202
,
1000
,
0
,
0
,
0
,
0
,
0
,
0*02<CR><LF>
7.2.16 Set NMEA output frequency
Command
:
242
Set NMEA sentence output frequency
Arguments:
Arg1: GLL
Arg2
:
RMC
Arg3:VTG
Arg4:GGA
Arg5
:
GSA
Arg6
:
GSV
Arg7:GRS
Arg8:GST
Arg9~Arg21:Remain
Example
:
$PGKC242,1,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0*37 <CR><LF>
7.2.17 Query NMEA output frequency
Command
:
243
Query NMEA sentence output frequency
Arguments
:
None
Example
:
$PGKC243*2A<CR><LF>
7.2.18 Return the NMEA output frequency
Command
:
244
Return the NMEA sentence output frequency (in response to the 243 command)
Arguments:
Args
:
Refer to 242 Commands
Example:
$PGKC244,1,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0*31<CR><LF>
7.2.19 Set reference coordinates
Command: 269
Set reference coordinates
Arguments
:
Arg1:

Table of Contents