EasyManua.ls Logo

Ebyte E108-GN Series - Set HDOP Threshold; Get HDOP Threshold; Version Number Query; Return the Current Version Number

Ebyte E108-GN Series
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co.,Ltd. E108-GN User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
2
25
7.2.25 Set HDOP Threshold
Command: 356
Set the HDOP threshold, when the actual HDOP is greater than the threshold, no positioning
Arguments:
Arg1:Threshold value
Example
:
$PGKC356,0.7*2A<CR><LF>639
7.2.26 Get HDOP Threshold
Command
:
357
Get HDOP Threshold
Arguments:None
Example:
$PGKC357*2E<CR><LF>
7.2.27 Version number query
Command: 462
Query the version number of the current software
Arguments: None
Example:
$PGKC462*2F<CR><LF>
7.2.28 Return the current version number
Command: 463
Return the version number of the current software (responds to the 462 command)
Arguments:None
Example:
$PGKC463,GK9501_2.0_Aug 10 2020,GOKE microsemi *3F<CR><LF>
7.2.29 Set location and time information
Command: 639
Set approximate location and time information for faster positioning
Arguments
:
Arg1: Latitude, eg: 28.166450
Arg2: Longitude, eg: 120.389700
Arg3: height, eg: 0
Arg4: Year
Arg5: month
Arg6: Day
Arg7: Hour, time is UTC time
Arg8: points
Arg9: seconds
Example:
$PGKC639,28.166450,120.389700,0,2017,3,15,12,0,0*33<CR><LF>
Remarks: Among them, the unit of latitude and longitude is degrees, and the height is meters