16
00H
Read / write
ADDH
ADDH (default 0)
Module address is high byte and low byte;
Note: When the module address is equal to
FFFF, it can be used as a broadcast and
listening address, that is, the module
will not filter the address
01H
Read / write
ADDL
ADDL (default 0)
02H
Read / write
NETID
NETID (default 0)
Network address, used to distinguish
networks;
When communicating with each other, set
it to be the same.
03H
Read / write
REG0
7
6
5
UART Serial Rate (bps)
The two modules of communication, serial
port rate can be different, calibration
mode can also be different;
When large data packets are launched
continuously, users need to consider the
data blocking caused by the same port
rate, or may even be lost;
It is generally recommended that the same
have the same the same.
0
0
0
The serial port port rate is
1200
0
0
1
The serial port port rate is
2400
0
1
0
The serial port port rate is
4800
0
1
1
Serial port port rate of 9600
(default)
1
0
0
The serial port port rate is
19200
1
0
1
The serial port port rate is
38400
1
1
0
The serial port port rate is
57600
1
1
1
The serial port port rate is
115200
4
3
Serial check bit
The communication two sides serial port
mode can be different;
0
0
8N1 (by default)
0
1
8O1
1
0
8E1
1
1
8N1 (equivalent to 00)
2
1
0
Wireless aerial rate (bps)
Both parties to communicate, the air
rate, must be the same;
The higher the air rate, the smaller the
delay, and a shorter the transmission
distance.
0
0
0
The air rate is 2.4k
0
0
1
The air rate is 2.4k
0
1
0
The air rate is 2.4k
0
1
1
Aerial rate of 2.4k
(default)
1
0
0
The air rate is 4.8k
1
0
1
The air rate is 9.6k
1
1
0
Aerial rate 15.6k
1
1
1
Aerial rate 15.6k
04H