PB-8010 H/T OPERATION
X7501200001 29
© 11/2018 ECHO Inc.
Starting Warm Engine
The starting procedure is the same as Cold Start except DO NOT close the
choke.
1. Throttle Lever
Move throttle lever (A) to IDLE
position.
2. Purge Bulb
Pump purge bulb (C) until fuel is
visible. Pump bulb an additional
4 or 5 times.
3. Recoil Starter
Pull recoil starter handle (D) and
engine should start. Do not use
choke (B).
Note: If engine does not start
after 5 pulls, use cold
start procedures.
PB-8010 H
A
PB-8010T
A
D
B
C