TALKOVER_ACTIVE
<Input=I4:I5>
Gets the current TALKOVER status (ON or OFF) for the specified
INPUT
TALKOVER_MODE
<Input=I4:I5>
Gets the TALKOVER function working mode (PAGER or DUCKER) for
the specified INPUT
TALKOVER_PRIORITY
<Input=I4:I5>
Gets the current TALKOVER PRIORITY level (LOW or HIGH) for the
specified INPUT
TALKOVER_ZONES
<Input=I4:I5>
Gets the current TALKOVER assignment to outputs (ZONES) for the
specified INPUT
TALKOVER_THRESHOLD
<Input=I4:I5>
Gets the current TALKOVER THRESHOLD LEVEL (dBx10) for the
specified INPUT
TALKOVER_DEPTH
<Input=I4:I5>
Gets the current TALKOVER DEPTH (attenuation, dBx10) for the
specified INPUT
TALKOVER_ATTACK
<Input=I4:I5>
Gets the current TALKOVER ATTACK TIME (milliseconds x10) for the
specified INPUT
TALKOVER_HOLD
<Input=I4:I5>
Gets the current TALKOVER HOLD TIME (milliseconds x10) for the
specified INPUT
TALKOVER_RELEASE
<Input=I4:I5>
Gets the current TALKOVER RELEASE TIME (milliseconds x10) for the
specified INPUT
CHIME_MELODY
<Input=I4:I5>
Gets the current CHIME MELODY selected for the TALKOVER function
in PAGER mode
CHIME_VOL
<Input=I4:I5>
Gets the current CHIME MELODY VOLUME (dBx10) adjusted for the
TALKOVER function in PAGER mode
XSELECT
<Input=I1:I5>
<Zone=ZA:ZD>
Gets the current CROSSPOINT SELECT status (ON (input active) or
OFF (input muted)) for the specified INPUT at the specified output
zone
XLEVEL
<Input=I1:I5>
<Zone=ZA:ZD>
Gets the current CROSSPOINT LEVEL (mix level) for the specified
INPUT at the specified output zone
ZONE_LABEL
<Zone=ZA:ZD>
Gets the current LABEL (name) for the specified output zone
ZONE_STEREO
<Zone=ZA:ZD>
Gets the current STEREO link status (ON or OFF) the specified output
zone