14
AUTOMATIC SMART WINTER MODE
The indicator appears in the display window when freezing temperature is detected and
flashes when the pump is active.
FILTER CYCLE
The FILTER CYCLE is composed of the following parameters: Filter Start Time (FS), Filter
Duration (Fd) and Filter Frequency (FF). A FILTER CYCLE consists of starting the pump on High
speed for 1 minute to purge possible air bubbles from the water lines and then running the
pump on Low speed for the remainder of the filter cycle duration, activating the Ozone
Generator, if so equipped, and introducing Ozone into the water supply via the Ozone Jet to aid
in sanitizing.
Factory Preset Defaults for the Filter Cycle are: Start Time: 12PM; Duration: 2 Hours; Frequency:
2 times per 24 Hours.
The icon shows solid in the display window when the Filter Cycle is active and flashes when
the Filter Cycle cannot activate or is suspended because the Jets are not on at Low speed.
Also, when your spa is in an active Filter Cycle you can suspend the Filter Cycle for 20 minutes
by pressing any button on the Topside Control panel. The icon will show flashing at this time
and again show solid once the Filter Cycle has resumed activity.
ECONOMY MODE
The ECONOMY MODE is composed of the following parameters: Economy Program (EP),
Economy Start Time (ES) and Economy Duration (Ed).
When the ECONOMY MODE is active, the display will toggle between the “Eco” message, the
current time, and the current water temperature. Factory preset default for the Economy Mode
is: EP, “0” (Disabled). When disabled, the Economy Start Time and Economy Duration settings
are irrelevant.
Our Smart Winter Mode function is preset at the factory to automatically
protect your spa from the cold by turning on the pump several times a day
to prevent water from freezing in the spa’s plumbing system. You do not
have to program this function and cannot alter it.
The ECONOMY MODE allows you to conserve energy during a certain period of the
day or over a number of days by minimizing operation of the Heater by temporarily
reducing the temperature set point of the spa by 20 °F (11 °C) during this
programmed cycle.