Heat Min On Time Sets the minimum
equipment run time in heat mode: 1 to 20 min
(default is 5 min).
Temp Correction
Lets you program an oset between the real
temperature at thermostat and the displayed
temperature. If you nd that the temperature
where the thermostat is located does not
represent the room temperature, change the
oset to compensate for the dierence. The
correct temperature is adjustable from +/- 10°F
in 0.5°F (0.3°C) increments.
Installer Code
To prevent accidental modications to the
installation settings, you can enable a 4-digit
installer code. This code is pre-programmed to
3262.
Test Equipment
These options let you test the wiring and
connections of the devices connected to the
thermostat by turning them on or o.
The equipment will turn o when you exit the
menu.
Warning: Compressor protection and
minimum run-time features are not
enforced while in this mode.
To test the equipment:
From the Home screen,
press MENU.
Select Settings
Installation Settings.
Select Test Equipment.
Select OK.
Test the equipment
connected to the
thermostat by turning each
component on and o.
!
30