SDi Decades Extreme Service Manual www.ecoer.com
May. 2023Manufacturer reserves the right to change specifications or designs without notice.
8.7.14 PC 08(Current overload protection)/PC 44(Outdoor unit zero speed protection)/ PC
46(Compressor speed has been out of control)/PC 49(Compressor overcurrent failure)
diagnosis and solution
Description: An abnormal current rise is detected by checking the specified current detection circuit.
Recommended parts to prepare:
Connection wires
Rectifier
PFC circuit or reactor
Blocked refrigeration piping system
Pressure switch
Outdoor fan
IPM module board
Outdoor PCB
Troubleshooting and repair: