SDi Decades Extreme Service Manual www.ecoer.com
May. 2023Manufacturer reserves the right to change specifications or designs without notice.
3.8 Electrical Characteristics
Capacity (Btu/h)
36k hyper Heat
60k hyper Heat
Power (indoor)
Phase
1
1
Frequency And Volt
208/230V,60Hz
Power (Outdoor)
Phase
1
1
Frequency And Volt
208/230V,60Hz
Max. Fuse
Indoor unit(A)
15
15
Outdoor unit(A)
50
60
Indoor unit Power line
Line quantity
3
3
Line diameter(AWG)
16/1.5mm²
16/1.5mm²
Outdoor unit Power line
Line quantity
3
3
Line diameter(AWG)
8/8.0mm²
8/8.0mm²
Outdoor-indoor Signal line
Line quantity
2
2
Line diameter(AWG)
20/0.5mm
2
20/0.5mm
2
Thermostat Signal line
Line quantity
Line diameter(AWG)
18/1.0mm
2
18/1.0mm
2

Related product manuals